Skip to content

Visualization

LightMind · documentation 1.0

Indoor / Residential: Engineering, Studio and Photometric modes are documented separately in Indoor 3D. Studio works without calculation; Photometric uses current Radiosity results. The road 3D workflow below retains its own scope.

Visualization helps you inspect geometry and read calculated data. A bright colour or white illuminated patch does not demonstrate compliance. Check the assessment, scope and warnings in Calculate.

  1. Activate the required Drawing → Model or the Assembly workspace.
  2. Open the View tab and choose 2D, Heatmap or 3D.
  3. For calculation layers, first obtain a current result using Calculate, or Calculate all for Assembly.
Mode What it shows
2D The basic CAD drawing without the calculation overlay.
Heatmap Grids, luminaire contributions, values and the legend over the 2D drawing.
3D A spatial view, a separate white Illuminated surface layer, and optional coloured calculation-field tiles.

The view mode and layer settings do not edit geometry. Returning to Home, opening View, or leaving that tab returns an individual Drawing to 2D; select the required mode again. Heatmap/3D return from a sheet to Model.

Use 2D to inspect road outlines, lanes, sidewalks, islands, poles, brackets, luminaire heads and CAD objects. Layer settings also affect visibility; a hidden object has not necessarily been deleted.

  • Use Zoom in, Zoom out, Fit on the View tab, or Fit all on the navigation bar.
  • Check position and mounting through Properties. A luminaire symbol alone does not confirm valid photometry.
  • For editing and Layers, see CAD tools, Route and Intersection.

The CAD GRID is a drafting aid. It is separate from Heatmap Mesh and does not change calculation points.

  1. After a successful calculation, select View → Heatmap.
  2. Open Heatmap Settings.
  3. Enable the required layers; enable Values and zoom into a field to read point values.
Setting Action
Mesh Master switch for the calculation overlay: fields, points, contributions and labels. Turning it off leaves a clean drawing.
Zones Outlines of points receiving a recorded contribution from each luminaire.
Colours Colours by luminaire; when disabled, a common neutral colour is used.
Combined Blends colours by contribution. When disabled, the strongest source determines the colour.
Values Values beside calculation points and the point detail in the panel. Off by default.
Legend The panel with luminaires, symbols and the explanation of a point value.
Opacity Changes visual density without changing calculated values.

Without an available grid, the settings are disabled with a Calculate hint. Enabling a layer from 2D opens Heatmap; a secondary layer also enables Mesh. Selecting 2D hides visualization while retaining its settings in the current session.

Showing or hiding the grid does not change its spacing. See Calculation fields and grids for grid generation and field limitations.

  1. Enable Mesh, Zones, Colours, Combined and Legend.
  2. Read S1, S2… as sequential calculation sources — individual luminaire heads. One physical pole can carry several sources.
  3. Hover close to a calculation point. Point value shows its total, contributing luminaires and shares. Without a hovered point, the panel selects an overlap detail or a critical point.
  4. Compare the total with the sum of contributions. Longer lists group the remainder under others.

Colours in 2D Heatmap identify sources, rather than lx or cd/m² ranges. A mixed colour indicates overlap. Halo size and density also depend on the value relative to the maximum in that field; saturation alone cannot compare absolute levels between different fields.

An evaluation-field outline is green for PASS and orange for other statuses. An orange outline alone does not distinguish FAIL from an incomplete assessment. Read the status and warnings. A contribution outline is not automatically the normative boundary of a lit area.

On a narrow screen, swipe the table horizontally to see all columns.

Display Data and units How to check it
2D Heatmap — points L [cd/m²] for an M carriageway; Eh [lx] for C/P and Conflict Area. The number is the engine value at that same point; check the metric and field.
3D — Heatmap layer Coloured tiles from available calculation fields. The palette is relative to the minimum/maximum of the displayed set; yellow does not mean PASS.
3D — Illuminated surface A separate physical Eh [lx] grid; in Route driver mode, L [cd/m²]. Read its own scale, unit and loading status.

At smaller scales, some numeric labels are omitted for readability; calculation points are not removed. Displayed values are rounded. Lavg/Eavg describe a field, rather than an arbitrary point.

The white layer interpolates between adjacent nodes. It uses a different grid from the evaluation field, and its intermediate tones are not a new normative assessment. Its legend has different scales for Eh, dry L and wet L; compare numbers and units when switching modes, not just appearances.

  1. Select View → 3D after calculating.
  2. Wait for the Illuminated surface status. The application may request an additional local calculation of the visualization grid, cached separately from the normative assessment.
  3. In Display, toggle Heatmap layer. This controls coloured tiles, rather than the white layer.
  4. For Route, choose Section: → All sections or an individual section.
  5. To inspect the white layer more clearly, turn off the coloured tiles and check its legend unit and scale.

The scene represents pavement, poles, brackets and assigned luminaire heads with simplified geometry. 3D is not a complete spatial copy of every CAD line, text and dimension, or a photorealistic material simulation.

Action Effect in the normal 3D view
Left-button drag Orbit around the scene.
Shift + drag or right-button drag Pan the view.
Mouse wheel Zoom in/out.
Double-click Reset the overall camera.
ViewCube Choose a direction when the cube is shown.

Orbiting and zooming do not recalculate lighting metrics.

  1. In Route 3D, enable Display → Driver view.
  2. Use the Driver POV settings button to open Driver POV and set Lane, Direction, Position · m, Eye height · m and FOV · °.
  3. Move along the lane with the wheel or vertical dragging. Select → Along the axis / ← Against the axis explicitly. Movement stops at the end if no connected lane is available.
  4. Choose Dry or Wet for the luminance map. It requires an M class and the corresponding dry/wet r-table; missing input or a C/P class can reject the map with a diagnostic.
  5. Turn Driver view off to restore the previous orbit camera and Eh layer.

Driver POV is a camera. Eye height, lane and movement settings do not move the photometric observer used for the L map. That map is calculated separately for the operative observer of each section; its position and road surface are stated in the status. Moving the camera does not reassess TI, Uo or another normative metric.

Context Confirmed behaviour and boundary
Route 2D Heatmap shows carriageway fields and available P zones. Coloured 3D tiles use carriageway fields; do not assume separate sidewalk P assessments are displayed there. Section scope and Driver POV are available.
Intersection The 2D grid and coloured 3D tiles cover Conflict Area. The white Eh layer uses separate approach and Conflict Area grids. Route Driver POV and dry/wet L maps are unavailable.
Assembly Geometry uses shared coordinates. Heatmap reads the global calculation and may include additional visualization points outside assessed zones. The white Eh layer is a separate resource clipped to pavement. There is no Route Driver POV for the whole Assembly.

Hiding a placed Drawing in Assembly does not define the normative assessment scope. An old global result is not treated as current after source changes. See Individual Drawing and Assembly for calculation scope.

Condition What to expect / check
No calculation Heatmap has no numeric layer; an ordinary Drawing in 3D reports no calculation for this drawing — press Calculate. Empty mountings can be shown geometrically without invented lighting.
White layer is loading or failed The status reports preparation, a missing grid or an error. Available normative tiles can remain visible.
Missing physical-grid value Cells without the required valid nodes are not drawn. An absent layer does not mean a measured zero.
Older record without numeric contributions The total point value may be available, but an unknown contribution appears as — and its sum is not confirmed.
Geometry or input changed The result can be marked outdated and the 2D layer faded. Check freshness before using the numbers.

For missing/deleted photometry, follow luminaire diagnostics. An old image does not prove that the current calculation succeeded: retaining an old PASS after failed Calculate is a known issue.

  • Luminaire colours in 2D, relative 3D tiles and the white layer have different meanings and scales.
  • Large grids are sampled for display; 3D interpolates between nodes. Display sampling does not change assessed values.
  • Schematic luminaire bodies do not provide verified manufacturer shapes, actual colour temperature or a complete reflection, shadow and obstruction simulation.
  • Missing/outdated data, unsuitable photometry and Calculate limitations also limit what the image can establish.

The reported issue with realistic white lighting remains subject to manual verification. An isolated check of the current code with valid synthetic photometry produced five Eh fields — four approaches and Conflict Area — and drew the white layer both with and without coloured tiles. Complete disappearance was not reproduced in this check; this does not confirm a realistic appearance in every project.

When checking, turn off Heatmap layer and distinguish a missing grid, covering coloured tiles and unsuitable visual tone. Valid Eh data should be represented consistently on the pavement. The issue has not been fixed, and the white effect must not be used as compliance evidence.

Input: one Intersection pole with two assigned luminaire heads. Current: the legend describes sources S1/S2 as Pole 1/Pole 2, although there is only one physical pole. Expected: separate head labels with correct membership of the shared pole. Until corrected, check the actual mounting through Properties; do not derive pole counts from these labels.

Input: an Intersection in 3D with Driver view selected. Current: the control and Dry/Wet can be enabled, but there is no Driver POV; the visualization request remains Eh. Expected: disable inapplicable controls or explain them clearly. A checked box does not establish a working Intersection luminance map. Both issues are recorded without application changes.