Calculations and assessment (Calculate)
Calculate computes lighting metrics and compares them with the implemented criteria for the selected class. PASS applies to the assessed fields and supplied data; it does not certify full normative compliance of the entire project. This verification also found software defects, which must be distinguished from a normative FAIL.
Before Calculate
Section titled “Before Calculate”Check the original Drawing in Model:
- Geometry, widths, lanes and pole positions are correct.
- Every participating head has accessible, suitable photometry. Check mounting and the photometric import limitations.
- The designer has chosen the class; initial M5/C4 values do not determine the required class automatically.
- An M assessment requires both the dry and the wet r-table. A missing table blocks Calculate before any computation — see the blocking inputs.
- An assigned sidewalk P class has an actual sidewalk area with positive width.
For creation and editing, see Route and Intersection. This chapter covers calculation without repeating geometry operations.
Run Route and Intersection calculations
Section titled “Run Route and Intersection calculations”- Activate the intended Drawing rather than the Assembly workspace.
- Open the LightMind tab and check EN class and MF.
- Open Settings… and check the applicable settings listed below.
- Click Calculate and wait for a result or diagnostics. Missing geometry/poles can disable the button with an explanation.
- Open Results for metrics and Compliance for the assessment and reasons for incomplete values.
For Route, the normal command calculates sections of the active Drawing. Selecting one section alone does not limit calculation to that section. For Intersection, its Conflict Area is assessed using a C class; long approaches and visible sidewalks do not automatically become separate normative zones.
An unchanged calculation input can reuse a saved result. After changes, check scope, input parameters and whether another Calculate is required; earlier numbers do not prove the current state.
Installed geometry and Declared design
Section titled “Installed geometry and Declared design”Route uses actual luminaire positions by default. installation · spacing, m in Properties declares pole spacing and affects field derivation; it does not move poles by itself.
Settings… → Declared design is a separate mode: for calculation, it arranges existing poles at the declared spacing, starting from the first pole along the Route. One common declared spacing is required; conflicting values are rejected. Actual Drawing geometry is not overwritten.
Check the model label and stations in the result. A Declared design result and installed geometry do not describe the same input. This option is not an Intersection mode or a setting of the global Assembly calculation.
Classes and implemented metrics
Section titled “Classes and implemented metrics”| Classes | Implemented assessment | Important limit |
|---|---|---|
| M1–M6 | Lavg, Uo, Ul, TI, REI, Uow. Lmin is informational. | Route; luminance requires an r-table and observer model. |
| C0–C5 | Eavg and Uo. | A Route field or an Intersection Conflict Area. |
| P1–P6 | Eavg and Emin. | A Route assigned a P class or its separate sidewalk P zones. |
| P7 | Numbers without normative thresholds for this class. | PASS with available data can mean no normative requirement, rather than proven P1–P6 quality. |
Limits come from LightMind’s embedded EN 13201-2:2015 criteria database. This list does not demonstrate independent verification of every calculation method and applicable standard requirement.
Calculation fields and grids
Section titled “Calculation fields and grids”The engine generates the normative grid. CAD GRID/SNAP do not determine calculation points. On narrow screens, swipe tables horizontally when needed.
| Case | Actual generation |
|---|---|
| Route, M | Applicable fields between successive poles or fields of the declared arrangement are assessed. Each field has 10 longitudinal positions up to 30 m; longer fields increase the count to keep spacing at most 3 m. Across the road: 3 points per lane. Points lie at cell centres. |
| Route, C | An illuminance field derived from pole spacing; 3 transverse points per lane. The longitudinal rule is the same as above. Read its start/end stations; do not assume the entire Drawing length was assessed. |
| Route, P / sidewalk P zone | A field on the corresponding band. Across it: at least 3 points and spacing at most 1.5 m; longitudinally, the same field-length rule applies. |
| Intersection | A polygon grid of cell-centre points inside the Conflict Area, excluding islands. Grid [m] sets desired spacing; actual X/Y spacing adjusts to the bounds without exceeding it. Initial value: 1.5 m. |
| Heatmap / 3D lighting | Uses calculation data and, depending on the view, an additional physical visualisation grid. This does not automatically add normatively assessed area. |
M has separate lane observers, 1.5 m high and 60 m before the field. The result identifies the operative observer. This is distinct from an arbitrarily positioned 3D camera.
For M, the governing field and unassessed strips are reported. Section numbers come from the governing field, rather than averaging all pole intervals. Large areas and small steps can make calculations costly or cause GRID_LIMIT in generators with point-count limits. Do not assume one universal limit for every grid type.
Calculation parameters
Section titled “Calculation parameters”| Control / input | Effect |
|---|---|
| EN class | Selects criteria. Route offers M/C/P; Intersection assessment requires C. |
| MF | Maintenance factor: 0 < MF ≤ 1, default 0.8. Affects maintained luminance/illuminance, without changing normative limits. |
| Settings… → Dry | Selects the dry r-table for M luminance. Selection is a Drawing property. Check the dataset’s provenance and eligibility label. |
| Settings… → Wet | A separate r-table for Uow; it is not derived automatically from the dry table. |
| Grid [m] | An Intersection calculation input. Disabled for Route, whose normative points derive from field, width and lanes. |
| Photometry and mounting | Sources are the assigned heads with their positions, heights, directions, tilts and applicable flux scaling. See Luminaires and photometry. |
C/P illuminance does not use an r-table as a reflection model. For M, both tables — dry and wet — are mandatory: a missing table blocks Calculate before the request (codes M_R_TABLE_REQUIRED and M_WET_R_TABLE_REQUIRED). The last valid result stays visible but is marked stale (“Recalculation needed”).
TI uses initial conditions with MF = 1. Reducing MF does not imply a proportional TI reduction. Uniformities are ratios and do not scale like Lavg/Eavg either.
Read the results
Section titled “Read the results”- In Results, check class, MF, active model and assessed sections/zones.
- Expand the intended section or Conflict Area. On a Route, the section label carries its number and bounding poles (for example “Section 4 · poles 5–6”). With a sidewalk P class, inspect the separate P zones too.
- In Compliance, compare values with displayed limits and read all reasons for unavailable metrics.
- Check start/end stations, point count, governing field and unassessed areas. Overall status does not represent one average luminance for the Route.
| Metric | Meaning / unit |
|---|---|
| Lavg / Lmin | Average / minimum luminance, cd/m². Lmin is informational. |
| Eavg / Emin | Average / minimum horizontal illuminance, lx. Their role as criteria depends on class. |
| Uo | Overall uniformity: minimum / average for the assessed quantity. |
| Ul | Longitudinal luminance uniformity. |
| TI | Threshold Increment, %; an inapplicable initial-luminance range gives a reason instead of a number. |
| REI | Edge Illuminance Ratio; a reason is supplied when the ratio cannot be formed. |
| Uow | Overall luminance uniformity using the wet r-table. |
“—” means missing/unavailable, rather than zero. The panel rounds values for readability while retaining the engine’s decision. For example, TI = 15.0001% against a 15% limit can display as “15” and remain FAIL. This alone is a rounding effect, rather than proof of an incorrect assessment.
Statuses and normative assessment
Section titled “Statuses and normative assessment”| Interface status | Interpretation |
|---|---|
| PASS | Implemented assessed criteria are met for accepted inputs. Check scope, P7 and known defects. |
| FAIL | An assessable zone/field violates a criterion. This is a normative failure of the calculated variant, rather than automatically a software defect. |
| Incomplete / INCOMPLETE | At least one required metric was not assessed. Resolve the cause; this is not PASS. |
| Input warning / INPUT_WARNING | Numbers are calculated, but the input photometry does not allow normative assessment. |
| Recalculation needed | Displayed results describe an earlier input. Run Calculate for the current state. |
With both unavailable metrics and a problematic I-table, the overall status can be Incomplete, while photometry warnings remain in diagnostics. Across zones the worst status is used: FAIL → INCOMPLETE → INPUT_WARNING → PASS. An overall FAIL can therefore coexist with incomplete assessment in another zone.
A red result caused by excessive pole spacing or insufficient light does not prove a bug. A software defect needs reproducible inputs and a current/expected behaviour difference; results should not be corrected manually.
Blocking inputs and warnings
Section titled “Blocking inputs and warnings”| Cause / code | Designer’s check |
|---|---|
| UNASSIGNED_LUMINAIRE | Assign photometry to the named existing position. A pole with no remaining heads is not a valid lighting installation either. |
| UNRESOLVED_PHOTOMETRY | The record is no longer available in the library. Assign a valid replacement; missing data are not replaced with zero intensities. |
| M_R_TABLE_REQUIRED | The M calculation has no dry r-table. |
| M_WET_R_TABLE_REQUIRED | The M calculation has no wet r-table, required for Uow. |
| INVALID_INSTALLATION | A valid field cannot be derived from the arrangement, for example one standalone pole without a neighbour/declared spacing. |
| P_ZONE_AREA_MISSING | A P class is assigned without a positive sidewalk area. |
| EMPTY_CONFLICT_GRID / INVALID_M_GRID / INVALID_E_GRID | Check the zone, islands, widths, lanes and field dimensions. |
| NONCONFORMING_I_TABLE | Check the photometric file’s input eligibility; successful import does not guarantee normative assessment. |
| GRID_LIMIT | Increase the allowed spacing of the applicable visualisation grid or reduce scope. Do not arbitrarily change the normative M grid rule. |
A rejection dialog can list multiple problems. Resolve their causes and calculate again. After rejection, do not treat retained old numbers as a new result — there is also a retained PASS without a stale indication defect.
Standalone Drawing and Assembly
Section titled “Standalone Drawing and Assembly”An original Drawing calculation uses its own sources. Calculate all in Assembly uses common world sources in the connected scope around the active element and assesses its zones. It is not an arithmetic sum of standalone reports.
- Each zone keeps its M/C/P class and criteria; light from a neighbouring connected Drawing can change results.
- Placements require 1:1 scale, available original Drawings and valid supported connections. An unconnected element is not automatically part of the active scope.
- At a Route/Intersection connection, area ownership is resolved separately from light contribution; an unsupported transition can block calculation.
- Display scope, visibility and camera position are not commands to restrict normative assessment.
- Check whether the displayed result is local or global. A synthetic single, untransformed Route case matched its standalone M metrics; this does not prove every possible composition.
Detailed composition workflows are described in the Assembly chapter.
Known limitations
Section titled “Known limitations”- Assessment depends on applicable fields, observers, actual geometry and input data. An unassessed strip is not automatically FAIL or PASS.
- Colour overlays and 3D are supporting views. Additional illuminated area does not extend normative scope or replace metrics.
- Limitations remain for manual flux with absolute tables, IES nominal flux and LDT measurement tilt.
Newly identified issues
Section titled “Newly identified issues”These cases were reproduced using in-memory data and isolated actual client code. The engine, database and real projects were not changed. Example inputs are diagnostic fixtures rather than completed lighting designs.
PASS with an ineligible r-table
Section titled “PASS with an ineligible r-table”Input: M6; straight section 60 m × 7 m, 2 lanes; poles at 0/20/40/60 m, lateral −4 m, height 8 m, outreach 1.5 m; MF 0.8; type-c-narrow.ies test photometry; constant dry and wet r-tables with r = 0.03, VERIFICATION_FIXTURE status and normativeEligible = false.
| Current result | Expected behaviour |
|---|---|
| PASS, qualified as a normative evaluation; Lavg ≈ 0.427896 cd/m², Uo ≈ 0.812504, TI ≈ 2.569395%. The ineligible-surface flag does not block the decision. | Block or explicitly qualify the assessment; do not issue normative PASS for a dataset declared ineligible. |
Check r-table provenance and eligibility independently of a green status. Do not use test/unverified datasets to demonstrate normative compliance.
Retained PASS after a failed Calculate
Section titled “Retained PASS after a failed Calculate”Input: saved PASS without a stale flag; the local Drawing is unchanged; the next Calculate receives UNRESOLVED_PHOTOMETRY, for example after a library record becomes unavailable.
| Current result | Expected behaviour |
|---|---|
| An error dialog is shown, but the retained PASS can remain without Recalculation needed. | Mark the old result stale/unverifiable or suppress its current verdict. |
After rejection, follow diagnostics. Restore valid input, refresh the document and complete a successful Calculate before treating old metrics as current.
Empty Route PASS through the calculation input
Section titled “Empty Route PASS through the calculation input”Input: a Route with class C4 or P3 and zero sections.
| Current result | Expected behaviour |
|---|---|
| The engine returns PASS with zero assessed sections. The normal Calculate button is disabled for the empty Drawing. | Reject missing geometry or return an explicit no-assessment state instead of PASS. |
An empty result is not a normative assessment. Check assessed section and zone counts.