Assembly combines Route and Intersection Drawings spatially for shared lighting calculations. Positioning uses the original Drawing’s shared position and can affect every Assembly referencing it. Read the coordinate rules before moving a placement.

Term Role
Project Contains Drawings and Assemblies.
Drawing An original Route or Intersection with its own geometry, poles, photometry and settings.
Placement A reference to a Drawing in an Assembly, with a label, visibility and position data.
Connection Joins specific ports and defines a connected component for global calculation.
Active element The root determining calculation scope. Selecting an object alone does not change it.

Each Drawing retains its original objects and standalone results. The global calculation has separate zones and results using contributions from the connected component. See Projects and Drawings for document organization.

  1. Open a Drawing in the required Project, then the Assembly tab.
  2. Click New Assembly. An empty Assembly is created in the current Project with an automatic name; no separate name dialog is required.
  3. Use Choose Assembly Project on the ribbon to open an existing Assembly.
  4. Return to the open Assembly using its document tab beside the Drawings. Select a Drawing tab to return to the original drawing.

Assembly is a separate working document: Home can operate on the displayed Assembly. Re-entering starts in 2D. Opening restores the saved global result, if present, with a freshness check.

  1. In Assembly, click Add Current. In the current interface this opens a palette of Project Drawings.
  2. Select a Route or Intersection. Adding preserves the original coordinates; it does not require a subsequent canvas click.
  3. Repeat for the remaining Drawings. Adding the same Drawing again through the ordinary Add action selects its existing placement.
  4. Use Select Drawing for the navigator and Fit All / Fit Active to inspect the scene.

The alternative Add Open and Add Existing actions depend on Open drawing, which remains empty and disabled in the checked CAD implementation. Use the working Add Current palette; see the selector limitation. These buttons are not a verified Windows file import path.

Place on Underlay is a separate tool: it selects a source Drawing and waits for a placement point. Check the coordinates and effect on the original before using it. DXF/PDF underlays provide reference material; they do not automatically supply road geometry, luminaires or evaluation zones.

For explicit port selection, open Assembly → Connections:

  1. Set First drawing and End port.
  2. Set Second drawing and Start port.
  3. Click Connect. The second Drawing aligns to the first; its existing connected component moves rigidly with it.
  4. Check the connection in Properties: state, distance, angular error and width difference.

You can also connect by clicking two free ports in the plan. The second selected element is the moving one.

Pair Support
Route END → Route START Supported. START/END are the ends of the complete Route Drawing.
Route ↔ Intersection approach port Supported, with an additional shared C/Route boundary check.
Intersection ↔ Intersection, matching Route ends, reuse of an occupied port Unsupported. A port belongs to one connection.

aligned means geometric alignment; width mismatch means aligned ports with an engineering caution. Neither is a normative assessment. A C/Route transition separately checks gaps, overlap, direction and full-width coverage; visually touching outlines can still form an invalid transition.

To edit a connection, select the specific Existing connection, then Re-align or Disconnect. Choose explicitly when several connections apply. Disconnect removes the connection while retaining current positions.

An original Drawing has one shared position. Saving MOVE, ROTATE, numeric positioning or Connect can write the change to the original and update all its placements. This is the implemented shared-position behaviour.

  • In Properties, Offset → X, m / Y, m is relative to Drawing coordinates. Additional rotation, ° supplies an additional angle.
  • After acceptance, the offset and additional angle return to zero: the new position is stored in the original Drawing. For example, X=10 m shifts the original geometry by 10 m; zero after saving does not undo the move.
  • The Placement dialog commits values through Apply or OK. Cancel closes an unaccepted edit.
  • Select complete placements for group MOVE / ROTATE. Moving only part of a valid connected group is rejected if it would break a connection, including one in another Assembly.
  • A Drawing’s scale is 1.000. Scaling a DXF/PDF underlay is a separate setting.

COPY of an entire placement does not create an independent Drawing and is rejected with SHARED_DRAWING_POSITION. Edit internal CAD objects in the original drawing editor using the CAD commands.

  1. Select a placement and use Open drawing in editor from Properties/the context menu.
  2. Edit the original Route or Intersection. Check that Properties identifies the intended object before moving geometry or poles.
  3. Return to Assembly. Its plan rereads original data and revisions; placements display the changed source.
  4. Check connections and C/Route transitions. Changing a length, width, Route end or Intersection approach can invalidate them.
  5. Update the global calculation if its input changed. When working in other windows, also use F5 to reread the active document.

Source geometry, poles and photometry are read from the original when generating a plan or calculating. Placement name is a placement-specific label. Remove removes the placement and its connections while retaining the original Drawing. Deleting a Drawing used by an Assembly is rejected with DRAWING_IN_USE.

Shared moves use linked history for originals and Assemblies. Undo/Redo can be rejected if a linked document has since been edited; a shared operation is not partially rolled back.

Assembly presents geometry in shared coordinates. A valid C/Route transition derives a common boundary and trims/assigns participating road domains to avoid duplicate evaluation area. It does not automatically merge all CAD objects into one editable Drawing.

Poles and individual luminaire heads come from the originals. Each source retains its mounting height, orientation and photometric data; positions and directions are transformed into the shared frame. Several heads on one pole are several calculation sources.

Assign and replace photometry in the original Drawing; see Luminaires and photometry. Missing library photometry is not replaced by zero contribution or a sample luminaire. Also check the newly identified disconnected-Drawing issue.

  1. Prepare classes, geometry, photometry and required road surfaces in the original Drawings.
  2. Select the visible Drawing that should define the scope root and click Set Active. The first added visible placement becomes active automatically.
  3. Check every connection in its connected component. A separate disconnected component requires its own activation and calculation.
  4. Click Calculate all and wait for the result or diagnostic.
  5. Read Results by Drawing and zone, as well as the overall status.

Scope is the active element’s connected component, rather than every visible Drawing. Show / Hide does not exclude a source from the normative calculation. The active element cannot be hidden; activate another first.

The current Calculate all command uses MF=0.8. It does not automatically inherit the last standalone Drawing MF or Declared design scenario. It uses actual shared positions and the original classes/road surfaces. See Calculate for metrics and input requirements.

On a narrow screen, swipe the table horizontally to see all columns.

Zone Assessment Contributions
Route — carriageway Implemented M/C/P criteria for its class; fields follow the available evaluation domain. Shared connected-component sources transformed into the zone frame.
Route — P zones Separate zones with their own P class, when specified. The same shared source list; separate metrics and assessment.
Intersection — Conflict Area Its C class and polygon grid, excluding islands. Includes contributions from connected Route Drawings.

The panel groups results by placement/Drawing and zone. Own sources counts that Drawing’s sources; sources in the shared scope is the full calculation list. Neither is a count of physical poles or proof of a nonzero contribution at every point.

The overall status follows the greatest severity: FAIL → INCOMPLETE → INPUT_WARNING → PASS. PASS applies to assessed zones and input, not complete certification of a Project. Standalone and Assembly results for a Drawing can differ because of shared light and the domain; compare matching scopes and MF.

An invalid C/Route transition can block calculation with ASSEMBLY_TRANSITION_GAP, ASSEMBLY_TRANSITION_OVERLAP or ASSEMBLY_TRANSITION_UNSUPPORTED. This diagnoses input; it is not a normative FAIL from calculated metrics. Missing mandatory metrics lead to an incomplete assessment. Read the reasons by zone.

Opening Assembly loads the latest saved global result and compares its calculation input with current originals, positions, connections and scope. Content checks detect changes even when a saved stale marker has not yet been set.

  • After a change, old values can remain available, explicitly marked outdated, requiring a new global calculation.
  • Restoring the same calculation input can make a matching saved result usable again.
  • Rereading/F5 does not launch a new normative calculation. Do not rely on continuous automatic synchronization between separate windows.
  • For missing/deleted sources or unresolved photometry, follow the diagnostic; an old PASS does not establish the current state.

Choose 2D, Heatmap or 3D in Assembly. Use View Settings for layers; see Visualization for detailed controls.

  • 2D: shared geometry, poles, heads, ports and connections; visibility controls the presentation.
  • Heatmap: grids from the global normative calculation and additional visualization points outside assessed fields. Additional points do not extend the normative assessment.
  • 3D: a shared spatial scene, white Eh layer and optional Heatmap layer. The white layer is clipped to pavement and has its own visualization calculation.

The white Eh layer uses all placed Drawings and their sources, including disconnected components. Its scope can differ from the current normative calculation. It can remain available while the normative result is outdated; it does not establish a current PASS. Assembly has no Route Driver POV for the complete composition.

  1. Open Reports and select the required objects in the report scope.
  2. Click Show selection. Inspect the separate Assembly source — results with shared lighting contributions — and its connected component.
  3. Check freshness, Drawings, zones and warnings. Disconnected components are considered separately; a result for one does not cover the others.
  4. Use the available PDF and Excel actions to export the prepared preview. After changing the selection or leaving report fields unsaved, first refresh/accept the preview.

Reports reads saved results and checks freshness; it does not start Calculate. Standalone and Assembly assessments retain separate provenance. Missing/outdated results must not be read as current PASS. With unassigned photometry the overall Project Report stays available: the specification is incomplete, with a clear diagnostic and no invented total power.

  • Route and Intersection Drawings are supported; a valid visible assembly does not guarantee a valid evaluation-domain transition.
  • Drawing scale must be 1.000. Older placements at a different scale can remain readable but are unsupported input for global calculation.
  • Shared position and linked history can affect several documents. Check the selection and rejection message before repeating an operation.
  • Underlays and the overall 3D scene are not independent evaluation zones or compliance evidence.
  • Photometry, Calculate and visualization limitations also apply to Assembly.

Input: an active C4 Route, 40 × 7 m, three heads with valid photometry; a second Route in the same Assembly, disconnected from the active one, with one unassigned head.

Current: the command is blocked by UNASSIGNED_LUMINAIRE for the disconnected Drawing. The engine and calculation scope include only the active component, but the preliminary API check visits every placed Drawing.

Expected: assignment checks should follow the chosen connected component. Until corrected, check photometry in disconnected placements too. This is a software issue in preliminary validation, rather than a normative FAIL. It is recorded without a fix.

Input: a loaded Assembly in the CAD ribbon. Current: Open drawing starts empty and disabled; no population path was found in the checked code. Dependent Add Open/Add Existing remain unavailable. An isolated check of the ribbon synchronization also confirmed this. Expected: a working chooser or clearly unavailable alternatives. Adding through the Add Current palette remains the working path. The application has not been changed.