Skip to content

Luminaires and photometry

LightMind · documentation 1.0

Start with an empty mounting position in the original Route or Intersection Drawing. Import a photometric file, assign the intended record and check the mounting before calculating. Importing alone does not assign a luminaire.

Term Meaning in LightMind
Photometric file A source IES or LDT file containing angles, luminous intensities and available manufacturer data.
Library record Parsed photometry with a name, format, reference and nominal flux when declared. One record can be used at many positions.
Mounting position / head A position for a luminaire on a pole and bracket. It can exist without assigned photometry.
Luminaire in a Drawing The specific head with assigned photometry and direction, tilt, rotation and flux parameters.

A pole is not a library record. The light source is at the outreach end, rather than the pole axis. In Intersection, multiple heads on one bracket share one photometry record.

Open LightMind → Library. The Photometry library dialog shows the name, format, nominal flux when available and filename. Select a row to use Assign or Delete; Close exits the dialog.

  • The library is read again when opened. It is not limited to the selected Drawing.
  • The first row may be selected initially. This does not assign it automatically.
  • Importing identical photometric content normally returns the existing record. A different filename does not guarantee a new record; also see the IES nominal flux limitation.
  • There is no confirmed editor for manually changing the I-table, symmetry or library names in this dialog. For different optics, import an appropriate file and replace the assignment.
  1. On the LightMind tab, click Load LDT / IES.
  2. Select one .ldt or .ies file.
  3. Read the message indicating successful import, an existing record or an error. Check the imported record in Library.
  4. Compare its name, format and nominal flux with the source. Then assign it to the intended position.
Format / check Supported behaviour and limit
IES (LM-63) Type C, with TILT=NONE. Type A/B and TILT tables are not supported by this import. Set installation tilt in the Drawing.
LDT (EULUMDAT) Supported Isym codes 0–4: no symmetry, axial, C0–C180, C90–C270 and quadrant. Compatible angles, a complete table and positive file flux are required.
Structure Empty, unrecognised or incomplete files, invalid angles, table dimensions and negative/non-numeric intensities can cause rejection.
Normative eligibility Angular coverage and I-table sampling are checked. A structurally readable file may import with issues that limit subsequent normative assessment.

Successful import does not prove normative eligibility. The valid photometry field in Properties also indicates an available assignment/data, rather than full confirmation of the photometric requirements. Check diagnostics after Calculate.

After successful import, the parsed table is held in the library record. Moving or deleting the original file on disk does not delete that record; LightMind does not reload it from its original path every time the Drawing opens.

  1. In Route, select a pole with one position, or a specific head when there are several.
  2. In Intersection, select a pole or its head. Assignment changes the shared photometry of that bracket.
  3. Open LightMind → Library, select a record and click Assign.
  4. Check the correct position and the photometry, from library and nominal flux, lm fields in Properties.

You can also use the existing Assign selector on the LightMind tab or from library in Properties. Without a specific target, the interface requests a selection. See Assign a luminaire to a pole for the short worked procedure.

In Assembly, open the original Drawing to edit assignments. Creating a pole, changing its arm count or opening the library does not select a luminaire automatically.

Select a pole or head and open Properties. The Edit pole panel is also available on the LightMind tab. Dimensions use metres, angles use degrees. On narrow screens, swipe tables horizontally when needed.

Field Practical meaning
height, m Mounting height of the source; positive.
outreach, m Distance from the pole axis to the head; zero or positive.
station, m / lateral, m Pole position in Route. Intersection uses world X/Y coordinates.
arms / angle between arms, ° 1–6 arms and an angle of 0–180°. Check the actual heads and their assignments.
orientation, ° Direction of the bracket/arms; affects the source positions.
direction (C-plane), ° Photometric direction of the selected Route head in the section’s local frame. Clearing the field restores following the arm. In Intersection it is derived and read-only.
tilt, ° In Route, set the calculation tilt on the selected luminaire. Changing only the pole mounting tilt does not replace that value. In Intersection, edit tilt on the pole; it is shared by its heads.
rotation, ° Additional photometric rotation about the vertical axis; separate from pole position and outreach length.

In Route, pole tilt is limited to −30°…+30°; do not treat this as universal validation for every tilt field. For geometric placement and editing, see Route and Intersection. For an intersection away from the origin, also check the initial orientation of a new pole.

  • nominal flux, lm comes from the file when declared; it is not edited as a second nominal value.
  • working flux, lm shows the selected value: a manual override or the file nominal.
  • flux override, lm accepts a positive manual value. Clear it to return to nominal. Replacing photometry through normal assignment clears the old manual flux and uses the new record’s nominal.

If the file declares no flux, this is indicated explicitly. The internal fallback of 1000 lm is not a measured manufacturer nominal.

To replace photometry, select the same head/bracket and assign another library record. Check the new nominal flux, orientation, tilt and rotation, then recalculate. Editing the I-table itself through Properties is not a confirmed feature.

To clear the assignment, select No luminaire assigned. The pole and position remain, without valid photometry for Calculate. In Intersection, this affects the shared bracket record.

ERASE / E is a different operation: it removes the selected object/head; erasing a pole removes its dependent heads. Assign requires an existing head/position. If the last ERASE operation removed the intended head, use Undo to restore it before assigning. See CAD / Modify. Drawing Undo/Redo is not a library recycle bin.

  1. Open Library, select a record and click Delete.
  2. Read the warning listing Drawings and positions that use it, including any usages found in history.
  3. Confirm only if you accept that affected references can be left without data. Cancel stops the operation.

A record being in use does not prevent deletion. Deleting it neither removes poles nor selects a replacement. Refresh the active document after changing the library. Assign an existing valid record to affected positions; reimporting a file is not a confirmed way to restore old references automatically.

State Opening / viewing Calculate
No assigned photometry The Drawing opens; the position remains No luminaire assigned. Nothing is assigned automatically from the library. UNASSIGNED_LUMINAIRE rejection naming the pole. This also applies to a pole with no remaining heads.
Library record deleted; Drawing holds only a reference The Drawing remains readable. On rereading it, Properties indicates missing/invalid photometry and requests a new assignment. UNRESOLVED_PHOTOMETRY rejection with unresolved reference locations. Missing data are not replaced with zero intensities.
Original disk file missing, library record still available The imported library table is used. The missing original file alone does not cause rejection.
Older Drawing holds its own embedded table The embedded table is retained. It can be sufficient even when its library reference is missing. Calculation from that table is possible if other checks pass; a filename alone is not treated as proof of missing data.

After rejection, identify the exact position, assign valid photometry, check the mounting and calculate again. For common settings and diagnostics, see the Surfaces and Calculate chapter.

Report preparation reads saved results and does not start Calculate. Missing library photometry makes the current assessment unverifiable. Clearing an assignment can make an old result stale; a previous PASS is not presented as current compliance.

A standalone Route/Intersection report can contain a diagnostic chapter without current metrics when no valid current result is available. Having a PDF/XLSX file alone does not mean calculation succeeded.

The I-table defines directional luminous intensity. The calculation source uses the actual head position, height, direction, tilt, rotation and applicable flux scaling. Mounting settings do not replace photometric data.

Run Calculate again after changing assignments or parameters. Heatmap and calculated 3D lighting use calculation data; changing display options or opacity alone does not change the I-table. An empty mounting position can appear as geometry without being a light source. A visible symbol or an old colour layer does not prove that current photometry is available and eligible.

  • Support covers the described IES Type C/TILT=NONE and LDT inputs, rather than every possible variant of these file families.
  • In Intersection, photometry, flux and photometric rotation are shared on the bracket. Assigning different optics independently to each of its heads is not supported.
  • Manual flux has the absolute-table limitation described above. Check numeric results as well as displayed lm.
  • The following two new issues were reproduced in memory using synthetic files. Real project data were not changed, and no fixes were made.

Different nominal flux on repeat IES import

Section titled “Different nominal flux on repeat IES import”
Current behaviour Expected behaviour
Two relative IES files with identical angles and I-tables but nominal flux of 1000 and 2000 lm receive the same duplicate identity. The second import returns the first record and its nominal. Different nominal flux that affects calculation intensities should remain distinct at import.

Compare the returned record’s nominal with the file. Renaming the file does not bypass this issue; an already-in-library message does not prove that the new nominal was imported.

Current behaviour Expected behaviour
Measurement tilt of 10° is parsed into the library record, but becomes 0° when passed into Drawing/engine photometry. Preserve measurement tilt and use it consistently in calculations.

Automatic compensation for nonzero LDT measurement tilt is not confirmed. It differs from manually entered installation tilt; such a file needs further verification before its results are used.