Residential — home lighting
Residential extends the existing Indoor workflow for homes. It uses the same CAD objects, real LDT/IES data, calculation engine, Radiosity and results, rather than a separate residential project system.
Choose the residential profile
Section titled “Choose the residential profile”When creating an Indoor project, choose Residential lighting. Use the real room contour and separate zones for different activities. The catalogue covers living rooms, bedrooms, kitchens, bathrooms, corridors, children’s rooms, dining rooms, stairs, home offices, garages and utility rooms.
Assign the function to a specific zone. Selection does not automatically change its contour, height, grid or luminaires.
Recommendations and design targets
Section titled “Recommendations and design targets”Residential values are labelled Recommended, with sources and conditions in the catalogue. They are not automatically normative EN 12464-1 requirements.
- Select a residential room function or activity through the existing catalogue.
- Explicitly accept a recommended value or enter your own lux target.
- For a range, choose a specific value; the system does not choose it for you.
- After calculation, compare actual E_m with the target in Results/Properties.
| Assessment | Meaning |
|---|---|
| Target achieved | The current calculated value reaches the target. |
| Below target | The value is below the target. |
| Missing, stale or incomplete result | There is no unconditional confirmation that the target is achieved. |
This is not normative PASS/FAIL. Comparison uses unrounded backend values. Edit or remove the target as needed; changing only the target does not trigger a new lighting calculation. With approximate photometry, the assessment is informational.
One interior, different scenarios
Section titled “One interior, different scenarios”Create named scenarios such as general lighting, evening, television or reading. These are workflow examples, not automatically added presets.
Set each luminaire’s enabled state and 0–100% luminous output. Results are stored separately for the active scenario. Dimming assumes linear luminous-flux control and does not invent electrical consumption values.
LED strips
Section titled “LED strips”The linear model accounts for actual length, orientation and distributed flux. Controlled segmentation improves numerical integration near receiving surfaces without doubling total flux when refined. Scenarios and dimming apply to the entire strip.
Use the actual available photometric data. A uniform-emission assumption or segmented far-field photometry is not a measured, exact near-field characteristic of the product.
Surfaces and furniture
Section titled “Surfaces and furniture”Evaluate a worktop at its actual height, a mirror plane with the correct normal, artwork, a floor at Z = 0 or an inclined surface. See receiving surfaces.
Insert → 3D library includes a bed, wardrobe, bedside table, chest of drawers, base and wall kitchen units, sofa and coffee table alongside existing workplace furniture. Place and edit objects freely; the software does not automatically furnish a room.
Doors and windows attach to a wall. Choose finishes and colours for the floor, ceiling and individual walls. Visual materials do not replace engineering reflectances. Only supported opaque geometry participates in direct shadowing; not all visual objects participate in all physical effects.
Use Studio to inspect materials without a calculation and Photometric for calculated illumination. See the three 3D modes.
Persistence and freshness
Section titled “Persistence and freshness”Functions, design targets, scenarios and dimming percentages use the existing Save/Open, Save As, .lmc and Undo/Redo mechanisms. Changes to geometry, photometry, height, MF or grid invalidate affected results. Returning to a valid stored combination may reuse the cache; switching scenarios does not import another scenario’s result.