Indoor — workplace and public lighting
Indoor uses LightMind’s shared CAD projects, drawings and photometry library. The Workplace and public lighting profile associates work zones with activities and applicable requirements from the existing EN 12464-1 catalogue. For homes, see Residential.
Room contours and work zones
Section titled “Room contours and work zones”- Create an Indoor project and activate the correct drawing.
- Define the closed room contour in 2D. L-shaped and U-shaped rooms are also supported.
- Set the height and engineering reflectances for the ceiling, walls and floor.
- Use the general zone and create the separate work zones you need. Each has its own height, grid and activity.
- Assign an activity to the selected zone through Insert → EN 12464-1 activity.
The activity belongs to that zone in the active drawing; it does not automatically propagate to other zones. Zero reflectance triggers a warning; the visual wall colour does not replace the engineering value.
Luminaires and photometry
Section titled “Luminaires and photometry”Use individual or group placement. Dynamic Input controls the parameters and preview shows candidate positions. For rectangular and supported L/U contours, placement follows the room geometry. Each luminaire remains an independent CAD object. Align arranges selected existing luminaires into a specified rectangular grid.
A luminaire may be placed without photometry and assigned an LDT/IES file later through Properties. A 3D housing is not photometry. Check the actual file, mounting height, rotation and tilt.
Calculation results show participating luminaires and those without photometry. Unassigned photometry must not produce a final compliance claim; a missing library record for already assigned photometry blocks calculation.
Receiving surfaces
Section titled “Receiving surfaces”| Surface | Example |
|---|---|
| Horizontal | Desk, kitchen worktop or floor exactly at Z = 0. |
| Vertical | Wall, artwork, mirror or kitchen splashback. |
| Inclined | Sloped work plane. |
Use the existing Work zone dialog for surface type, Z, azimuth, inclination, normal and grid spacing. The normal determines the illuminated side. Vertical surface illuminance is different from cylindrical E_z.
Scenarios and dimming
Section titled “Scenarios and dimming”In LightMind → Lighting scenarios, create named variants and set each luminaire’s enabled state and 0–100% output. Select and calculate the active scenario. Results and cache are separate per scenario and zone; input changes invalidate affected calculations.
The percentage scales luminous flux. This assumes linear dimming rather than a measured driver curve; it does not imply linear electrical consumption. Disabled luminaires and 0% output have no light contribution.
Structures, openings and library
Section titled “Structures, openings and library”Use Insert → Assign structure to link the 2D contour to a metal structure with insulated panels, masonry construction or timber construction. Rectangular, L-shaped and U-shaped contours are supported. The structure follows the contour without replacing the room’s engineering settings.
The existing 3D library includes doors, windows, structural elements, materials, furniture and luminaire housings. Doors and windows attach to a wall with a real visual opening. Edit dimensions, position and supported opening directions through CAD/Properties. Three-leaf and four-leaf windows are also available.
Choose materials and colours independently for walls, individual walls, floor and ceiling. Visual PBR settings do not automatically change engineering reflectances.
The three 3D modes
Section titled “The three 3D modes”| View → Display | Purpose |
|---|---|
| Engineering | Technical inspection of geometry and available calculation layers. |
| Studio | Materials and neutral studio lighting without a lighting calculation. This is not an engineering prediction of illumination. |
| Photometric | Uses current LDT/IES and spatial Radiosity results. A missing current surface mesh requires calculation. |
Mode switching uses the shared progress banner. Camera and exposure change presentation, not numerical lux results. Visual shadows are not an additional engineering light contribution and do not prove compliance.
Results, freshness and compliance
Section titled “Results, freshness and compliance”In Results, distinguish All metrics from Compliance. The first shows calculated values; the second shows applicable requirements and assessments. Contextual Properties is for the selected object’s settings.
- E_m, E_min, E_max and U₀ describe the relevant zone and grid. E_z, E_w, E_c, Ra and UGR depend on available data and applicability.
- CURRENT requires matching actual inputs and a valid stored result. Physical changes require recalculation; STALE is not a current assessment.
- The numerical E_z warning checks convergence, rather than measuring the error in the average value. Read the diagnostics.
- For UGR, distinguish no requirement, an inapplicable method and a successfully assessed result. Observer UGR is informational and does not automatically receive normative PASS/FAIL.
- If a required metric is unassessed or the luminaire set is incomplete, passing the remaining checks does not establish overall compliance.
Physical limitations
Section titled “Physical limitations”Radiosity handles reflections within the supported model. Supported opaque furniture participates in direct shadowing through its actual triangular geometry. This does not imply full modelling of blocked indirect exchange, furniture reflections or glass transmission. Active E5-B/E5-C is not claimed.
CIE 117/CIE 190 applicability is checked separately. Neither Studio nor Photometric imagery alone proves normative compliance or measured visual accuracy.