Known issues and limitations
LightMind · 1.0
The state was synchronized with the LIVE sources on 15 October 2026. The two defects from the 13 October 2026 inventory — the message after an r-table selection and the overall Project Report aborting with unassigned photometry — are fixed and covered by targeted tests. The following limitations remain.
LightMind 1.0.5.0 is now published in Microsoft Store. Installation options are on the Download page.
Limitations
Section titled “Limitations”- Supported criteria cover M1–M6, C0–C5 and P1–P6; P7 has no normative requirements.
- Assembly requires scale 1:1 and valid connections. An operation that would break a valid connection is refused atomically with
CONNECTION_BREAKS_EXISTING— see Connect Drawings. - An M class requires both the dry and the wet r-table; a missing table blocks Calculate before computation — see the blocking inputs.
- Photometric import is limited to supported IES Type C/TILT=NONE and LDT inputs.
- Heads on one Intersection bracket share photometry.
- Open Assembly pre-check questions are described in the Assembly chapter.
Module limitations are also described in the corresponding documentation chapters.
New Indoor and Residential capabilities — scope
Section titled “New Indoor and Residential capabilities — scope”Checked against local code and reports on 17 November 2026, without browser or visual verification. Publication of Store candidate 1.0.6.0 is not confirmed.
- Residential lux targets and recommendations do not automatically establish normative compliance.
- Studio is not a lighting result; Photometric requires current local calculation data.
- UGR may be inapplicable; a missing required metric is not replaced with invented PASS/FAIL.
- LED segmentation and linear dimming have explicit modelling assumptions.
- Direct shadowing by supported opaque furniture is implemented; full E5-B/E5-C obstruction of indirect exchange is not claimed.
- Appearance, PBR materials and visual structures are not automatically physical coefficients or participants in every calculation effect.
See Indoor and Residential.